A lifeline is never the first answer. Both Quebec and Ontario require the risk to be eliminated first, then handled collectively with a guardrail. A harness tied to an anchor comes only afterwards, when the earlier solutions are not achievable.

This page sets out what the two regulations require once that point is reached: the permissible arresting force, the tolerated free fall distance, the anchorage strength and the standards each province names.

To understand why a guardrail comes before a harness, see the hierarchy of prevention measures. To choose a system, see our lifelines and anchors.

The same threshold, twice

In Quebec as in Ontario, the duty to protect a worker against falls is triggered beyond 3 m (9.8 ft). It is the only point on which the two regulations say exactly the same thing.

QUEBEC

RSST, sections 33.1 and 33.2

Any worker exposed to a fall of more than 3 m (9.8 ft) must be protected. The employer applies the hierarchy of prevention measures, in which a harness tied to an anchorage system ranks last.

ONTARIO

Regulation 851, section 85, and O. Reg. 213/91, section 26

In an industrial establishment, a worker exposed to a fall of more than 3 m (9.8 ft) must wear a serviceable safety belt or harness, tied to a lifeline adequately secured to a fixed support (Regulation 851).

On a construction project, including much rooftop work, O. Reg. 213/91 applies instead. Fall protection is required beyond 3 m (9.8 ft), from 1.2 m (3.9 ft) above a wheelbarrow path, and at any height where a worker could fall into operating machinery, into a liquid, onto a hazardous substance or object, or through an opening.

The threshold opens the obligation, it does not describe the system. A harness clipped to a questionable point meets the threshold and protects no one. Everything that matters comes after: what the connection is made of, what it is tied to, and what the assembly has to absorb.

What the RSST requires, section by section

Quebec is prescriptive. Four sections describe the whole chain, from the harness to the supporting structure, and name eight CSA standards.

SECTION 347

The harness

Compliant with CAN/CSA Z259.10, tied by a fall arrest connection to an anchorage system. The complete assembly must limit the maximum arresting force to 6 kN and the free fall distance to 1.8 m (5.9 ft).

SECTION 348

The fall arrest connection

  • Energy absorber and lanyard compliant with CAN/CSA Z259.11, maximum length 2 m (6.5 ft)
  • or a self-retracting device compliant with CAN/CSA Z259.2.2
  • Rope grab compliant with CSA Z259.2.5 or CSA Z259.2.4
  • Vertical lifeline compliant with CSA Z259.2.5 or CSA Z259.2.4, under 90 m (295 ft), one person only
  • Connecting components compliant with CAN/CSA Z259.12
SECTION 349

The anchorage

Point anchorage: strength of 18 kN (about 4,000 lb), or engineered to CSA Z259.16 at twice the maximum arresting force, with an anchor connector certified to EN 795 or CAN/CSA Z259.15.

Continuous flexible: steel cable of at least 12 mm (1/2 in), 12 m (39 ft) maximum between anchors, end anchors of 90 kN (about 20,200 lb), maximum slope of 1 in 12, two workers at most.

Continuous rigid: engineered to CSA Z259.16.

SECTION 349.1

Conditions of use

  • One person at a time, unless the system is continuous
  • Horizontal displacement of the D-ring limited to 3 m (9.8 ft) or an angle of 22°
  • No unintentional detachment of properly attached equipment
  • The supporting structure must take the system's forces on top of its usual loads

What Ontario requires: two regulations depending on the workplace

In Ontario, the applicable regulation depends on the workplace. In an industrial establishment, it is Regulation 851, which fits into a single section. On a construction project, including much rooftop work, it is O. Reg. 213/91, which is far more detailed.

INDUSTRIAL ESTABLISHMENTS

Regulation 851, section 85

  • Beyond 3 m (9.8 ft), a serviceable safety belt or harness
  • Tied to a lifeline adequately secured to a fixed support
  • Free fall limited to 1.5 m (4.9 ft)
  • Maximum arresting force limited to 8.0 kN
WHAT IT LEAVES UNSAID

The silences of Regulation 851

  • No CSA standard named
  • No minimum anchorage strength, point or continuous
  • No full body harness mandated: a safety belt remains admissible under the text
CONSTRUCTION PROJECTS

O. Reg. 213/91, sections 26 to 26.9

  • A mandatory order of preference: a guardrail first, then, where it is not practicable, a travel restraint system, a fall restricting system, a fall arrest system and, last, a safety net
  • For fall arrest, a full body harness is mandatory, with a lanyard fitted with a shock absorber
  • Maximum arresting force limited to 8 kN, with no possible contact with the ground or a lower level
  • Temporary fixed support able to withstand 8 kN for fall arrest (6 kN with a shock absorber), 6 kN for fall restricting and 2 kN for travel restraint
  • Horizontal lifelines designed by an engineer, with the design kept on the project for as long as the system is in use
  • Eight CSA Z259 series standards named for components, written rescue procedures before any fall arrest system is used, and working at heights training (O. Reg. 297/13)

Regulation 851, for its part, sets no anchorage value and names no standard. This economy of means does not lower the requirement, it moves it: it falls to whoever designs and installs the system to show that the anchorage holds, and the only technical reference available remains the CSA Z259 series.

Our systems are sized on the Quebec values, the highest, which places them above what both Ontario regulations ask on arresting force and on anchorage alike. That leaves the one point on which Regulation 851 is stricter: free fall, tolerated at 1.5 m (4.9 ft) against 1.8 m (5.9 ft) in Quebec. On an Ontario construction project, we also check the requirements specific to O. Reg. 213/91, starting with the engineered design of horizontal lifelines.

Quebec and Ontario, point by point

The table below compares the regulations on the values that drive the design of a system.

  Quebec, RSST Ontario, Regulation 851 (industrial) Ontario, O. Reg. 213/91 (construction)
Protection threshold 3 m (9.8 ft) 3 m (9.8 ft) 3 m (9.8 ft), 1.2 m (3.9 ft) above a wheelbarrow path
Equipment Harness compliant with CSA Z259.10 Safety belt or harness Full body harness for fall arrest
Maximum free fall 1.8 m (5.9 ft) 1.5 m (4.9 ft) No contact with a lower level; 0.6 m (2 ft) for fall restricting
Maximum arresting force 6 kN 8.0 kN 8 kN
Point anchorage 18 kN (about 4,000 lb), or engineered to CSA Z259.16 Not specified Temporary fixed support of 8 kN (6 kN with a shock absorber)
Continuous flexible anchorage Cable of at least 12 mm (1/2 in), 12 m (39 ft) between anchors, end anchors of 90 kN, two workers at most Not specified Engineered design required, kept on the project
Standards named Nine CSA standards, plus EN 795 None Eight CSA Z259 series standards
Reference text RSST, sections 33.1, 33.2 and 347 to 349.1 Regulation 851, section 85 O. Reg. 213/91, sections 26 to 26.9

Neither province is uniformly stricter than the other. Quebec governs arresting force and anchorage strength more tightly. In Ontario, Regulation 851 is stricter on free fall, and O. Reg. 213/91 requires an engineer for any horizontal lifeline. For a client operating sites in both provinces, the design is therefore built on the tighter value of each line, not on one province's regulation.

Each standard, its system

The nine CSA standards named by the RSST fall into three product families. Here is what applies to what.

Horizontal systems

CSA Z259.13 covers manufactured horizontal lifeline systems. CSA Z259.16 covers the design of custom active systems.

Horizontal cable lifeline
Horizontal rail lifeline

Vertical systems

CSA Z259.2.5 for flexible vertical lifelines and their rope grabs. CSA Z259.2.4 for vertical rigid rails.

Vertical lifelines

Anchors

CSA Z259.15 for anchor connectors, with EN 795 recognised as an alternative by section 349 of the RSST.

Anchor points and systems

Personal equipment

CSA Z259.10 the harness, CSA Z259.11 energy absorbers and lanyards, CSA Z259.2.2 self-retracting devices, CSA Z259.12 connectors.

Personal protective equipment

A tenth standard is worth knowing even though the regulation does not impose it: CSA Z259.17, on the selection and use of fall protection equipment. It answers the questions the regulation leaves open, chief among them the calculation of fall clearance.

Frequently asked questions

At what height does a lifeline become mandatory?

Neither province mandates a lifeline at a given height. They mandate fall protection beyond 3 m (9.8 ft). A lifeline is only one of the possible answers, and it comes after eliminating the risk and after a guardrail. It becomes the chosen solution when collective protection is not achievable.

Which regulation applies to rooftop work in Ontario?

If the work is part of a construction project, O. Reg. 213/91 applies: full body harness for fall arrest, specified fixed support strength, and horizontal lifelines designed by an engineer. In an industrial establishment outside a construction project, Regulation 851 applies. The line is not always obvious: our technical team can help you identify which regime applies to your project.

Is a system designed for Quebec compliant in Ontario?

Not automatically. The Quebec values are higher on arresting force and anchorage strength, but Regulation 851 is stricter on free fall distance, tolerated at 1.5 m (4.9 ft) against 1.8 m (5.9 ft) in Quebec. On a construction project, O. Reg. 213/91 also requires horizontal lifelines to be designed by an engineer. These are the points to re-check on any Ontario project.

How many workers can use a horizontal lifeline at the same time?

In Quebec, section 349 of the RSST limits a continuous flexible anchorage system meeting the prescribed values to two workers at a time. A system engineered to CSA Z259.16 may allow a different number, which is then stated on the plan. On an Ontario construction project, the engineer's design required by O. Reg. 213/91 also states how many workers can safely attach to it.

Is an EN 795 certified lifeline accepted in Quebec?

Section 349 of the RSST names EN 795 explicitly, as an alternative to CAN/CSA Z259.15, for the anchor connector of a point anchorage system designed and installed to an engineer's plan. For a complete horizontal line, compliance is established differently: either through the values prescribed in section 349, or through an engineered design to CSA Z259.16.

Does installing a lifeline require an engineer?

In Quebec, not always. A point anchorage withstanding 18 kN (about 4,000 lb) meets the regulation without an engineer's plan. As soon as the system departs from the prescribed values, or is a continuous rigid anchorage, section 349 requires an engineered design to CSA Z259.16. On an Ontario construction project, every horizontal lifeline must be designed by an engineer (O. Reg. 213/91). In all cases, the supporting structure must take the system's forces, which means verifying it.

On a fixed ladder, lifeline or cage?

The two provinces diverge sharply on this point. See fixed ladders in Quebec and fixed ladders in Ontario.