The regulatory framework: RSST, sections 23 and 24

In Quebec, fixed ladders used to replace a service stairway are governed by sections 23 and 24 of the Regulation respecting occupational health and safety (RSST). Administered by the CNESST, this regulation sets out precise requirements for construction, load resistance, and fall protection.

Required dimensions and load resistance

Under section 23 of the RSST, a fixed ladder must be of sound construction and securely fastened to support a mass of 90 kg (198 lb) at the centre of the rungs, with a safety factor of 4. It must also provide a clearance of at least 150 mm (6 in) behind the rungs, at least 800 mm (31 in) in front, and at least 375 mm (15 in) on each side, measured from the centre of a rung.

The ladder must extend at least 900 mm (35 in) above the upper landing and, where it provides access to a floor opening, be surrounded by a guardrail with a removable barrier.

At what height does a fall arrest device become mandatory?

Wherever there is a fall hazard of more than 6 m (20 ft), the RSST requires the fixed ladder to be equipped with a fall arrest device compliant with CSA Z259.2.5 (fall arresters and vertical lifelines) or CSA Z259.2.4 (fall arresters and rigid rails).

What changed on January 3, 2019

Before that date, a fixed ladder could be considered compliant if fitted with a cage, a well, or a fall arrest device compliant with the former CAN/CSA Z259.2.1-98 standard. Since January 3, 2019, only fixed ladders already installed by that date may keep a cage or well until they are modified.

For any fixed ladder installed or modified since then, a fall arrest device compliant with CSA Z259.2.5 or CSA Z259.2.4 is mandatory wherever the fall hazard exceeds 6 m (20 ft): a cage or well alone is no longer recognized as compliant protection.

Rest platforms for ladders over 9 m (30 ft)

For any fixed ladder over 9 m (30 ft) in height, the RSST requires rest platforms with guardrails, installed at intervals of no more than 6 m (20 ft). Section 24 provides an exception for permanent ladders serving elevated towers, water towers, or other tall structures where workers have only occasional access.

RSST requirements summary

Load of 90 kg (198 lb) at the centre of the rungs (safety factor 4), rear clearance of 150 mm (6 in), front clearance of 800 mm (31 in), side clearance of 375 mm (15 in) on each side, 900 mm (35 in) landing overrun, rest platforms required every 6 m (20 ft) beyond 9 m (30 ft) in height, and a CSA Z259.2.5 or CSA Z259.2.4 fall arrest device required beyond a 6 m (20 ft) fall hazard.

Requirement (RSST, s. 23-24) Value
Load at centre of rungs 90 kg (198 lb), safety factor 4
Rear clearance of rungs 150 mm (6 in) minimum
Front clearance 800 mm (31 in) minimum
Side clearance 375 mm (15 in) minimum on each side
Landing overrun 900 mm (35 in) minimum
Rest platform threshold required every 6 m (20 ft) if ladder > 9 m (30 ft)
Fall arrest device threshold required if fall hazard > 6 m (20 ft)
Accepted standards (fall arrest device) CSA Z259.2.5 or CSA Z259.2.4 (installations since January 3, 2019)

Why choose Échelle Canada ?

Échelle Canada designs every Fixup fixed ladder to measure, based on the actual height of the building, machine, or maintenance area it serves. Fully manufactured in aluminum, welding-free, it assembles quickly on site from a small number of base parts (ladder sections, hoops, mounting brackets), with all hardware delivered pre-fitted.

Where the fall hazard exceeds 6 m (20 ft), our advisors build the fall arrest device suited to your installation into the design. We also offer a range of security hoops with a locking access gate, an effective way to restrict ladder access to authorized personnel only and limit the risk of intrusion on your roofs and technical areas.

Search for an Echelle Canada store

Take advantage of our powerful network and benefit from the best prices year-round on more than 6,000 products.

See on the map

Frequently asked questions

At what height must a fixed ladder in Quebec be equipped with a fall arrest device?

Wherever there is a fall hazard of more than 6 m (20 ft), under section 23 of the RSST.

Is a cage or well enough to be compliant?

Not for a fixed ladder installed or modified since January 3, 2019. Only ladders installed before that date may keep a cage or well until modified.

What load must a fixed ladder be able to support?

A mass of 90 kg (198 lb) at the centre of the rungs, with a safety factor of 4.

Are rest platforms required on a long fixed ladder?

Yes, for any ladder over 9 m (30 ft), at intervals of at least every 6 m (20 ft), except as provided in section 24 for occasional-access structures.