It is the simplest part of a fall protection system, and the one everything rests on: if the structure does not hold, the harness, lanyard and energy absorber are of no use.
Section 349 of the RSST sets the rule: a point anchorage must withstand 18 kN (about 4,000 lb), or be engineered to CSA Z259.16, with its anchor connector certified to EN 795 or CAN/CSA Z259.15. See the Quebec and Ontario requirements ›
Four families, according to what is underfoot
Choosing an anchor works the opposite way round from intuition: you start from the existing support, not from the point to be created.
On the supporting structure
Dedicated plates for concrete, steel deck, steel frame, timber and zinc. Each support has its plate, the anchor point itself does not change.
The galvanised steel anchor post, made up of a ring and a collar that preserves the waterproofing, fixes to a concrete slab, a steel beam or a timber beam using a backing plate.
Posts and stanchions
Stainless steel posts of 150 mm (5.9 in) and 300 mm (11.8 in), with custom manufacture from 150 to 1,000 mm (5.9 to 39.4 in).
Rigid posts for concrete in 500, 700 and 1,000 mm (19.7 / 27.6 / 39.4 in), plus a wall-offset version at 23 cm (9 in). They take rail and cable lifelines alike, and any EN 795 type A, C or D anchor point from the range.
Interfaces for waterproofed roofs
This is the case that stalls a project most often: piercing a waterproofing membrane to fit an anchor. The interfaces for zinc roofing and for standing seam install directly onto the waterproofing build-up, with no work from below.
Supplied with 180 mm (7.1 in) stainless steel toggle bolts, stainless cap nuts, a sealing washer and EPDM gaskets. Two standing seam versions cover spacings of 290 to 430 mm (11.4 to 16.9 in) and 460 to 600 mm (18.1 to 23.6 in).
Raising and slope compensation
A 100 mm (3.9 in) riser and a 250 mm (9.8 in) tilting stanchion raise the line and make room for the energy absorber or the tensioner at the start of the run.
An articulation compensates a roof slope to align the supports. On the tilting stanchion, the shear elements give way beyond 170 daN (1.7 kN) and the post extends by 4 cm: the line's deflection then rises sharply, which calls for closer support points, with a maximum recommended spacing of 10 m (32 ft).
The admissible clamping widths on rigid posts remain subject to validation by our design office, which reviews the file before ordering.
When there is nothing to tie onto
Some work areas offer no structure able to take an anchor. A maintenance bay, a siding, a wash area. The free-standing gantry brings its own structure.
No civil works
The concrete ballast is built into the gantry, at 1,500 kg (3,307 lb) per module. There is no excavation, no poured foundation and no curing time.
Relocatable
The gantry moves from one station to another. That is the difference from an anchored gantry, and what makes it relevant to an activity that changes location.
Short fall clearance
It is sized to take an EN 795 type A anchor point or a rail lifeline. Paired with a 6 or 10 m (20 or 33 ft) self-retracting device, it handles situations where the clear height below the worker is limited.
The height and offset of the anchor point can be changed, and the gantry's dimensions adapted as needed. A prior study remains preferable to settle on the best configuration. Request a study.
Frequently asked questions
Anchor point or lifeline?
An anchor point secures a position, a lifeline secures a movement. If the work happens at one precise spot that is returned to every time, a point anchor is enough and costs considerably less. As soon as the worker has to travel across a roof, a walkway or a ladder without unclipping, a continuous system is needed: cable, rail or vertical.
What strength must an anchor offer?
In Quebec, section 349 of the RSST opens two routes. Either the point anchorage withstands 18 kN (about 4,000 lb), or it is designed and installed to an engineer's plan following CSA Z259.16, with a strength equal to twice the maximum arresting force and an anchor connector certified to EN 795 or CAN/CSA Z259.15. Ontario sets no value: Regulation 851 asks for a lifeline adequately secured to a fixed support, without specifying a strength.
How many people per anchor?
One at a time. Section 349.1 of the RSST reserves an anchorage system for one person, unless it is a continuous system, a horizontal lifeline or a rigid rail. The same section limits the horizontal displacement of the harness D-ring to 3 m (9.8 ft) or an angle of 22°, which in practice determines how many points a work area needs.
Can you anchor onto a waterproofed roof?
Yes, using interfaces designed for it. They install onto the waterproofing build-up with no work at all from below, and sealing is handled by a dedicated washer and EPDM gaskets. This point often decides whether a roof project is feasible, before the choice of system even comes up.
Is an EN 795 certified anchor accepted in Quebec?
The Quebec regulation names that standard. Section 349 explicitly admits an anchor connector certified to EN 795, as an alternative to CAN/CSA Z259.15, in the case of a point system designed and installed to an engineer's plan. Our anchors meet the requirements of the RSST and the applicable CSA standards, and are certified to EN 795:2012.
What if no structure can take the anchor?
That is the situation the free-standing gantry addresses. It brings its own mass, with no civil works or poured foundation, and moves from one station to another. It takes an anchor point or a rail lifeline, and pairs with a self-retracting device where clear height is limited.
An area to secure, a structure you have doubts about? Talk it through with our technical team.