When must a worker be protected against falls?
Section 33.1 of the RSST sets out the situations in which a worker must be protected against falls.
- When exposed to a fall of more than 3 m (9 ft 10 in) from their working position
- When at risk of falling from at least 1.5 m (4 ft 11 in) into a well, a basin, a vat or a tank
- When at risk of falling into a dangerous liquid or substance, or onto moving equipment
The only case excluded from the 3 m threshold is a worker who is merely using a means of access or exit.
The hierarchy of prevention measures
Section 33.2 sets an order of priority. The employer must apply the first workable solution, and move to the next one only when it is not.
| Rank | Prevention measure |
|---|---|
| 1 | Change the working position so the task can be carried out at ground level |
| 2 | Install a guardrail, or a system limiting the worker's movement |
| 3 | Use a safety net |
| 4 | Require a harness connected to an anchorage system by a fall arrest connecting device |
| 5 | Use a means providing equivalent safety |
This order has a direct consequence on site: the harness is not the first answer to a fall hazard, but the fourth. A platform fitted with guardrails, a protected walkway or a stair with handrails meets the requirement without having to equip and train every worker.
When is a guardrail mandatory?
Section 33.3 sets out the cases in which a guardrail must be installed at the edge of the opening.
- From 1.5 m (4 ft 11 in) where the fall would be into a dangerous liquid or substance, or into a well, a basin, a vat or a tank
- Above 3 m (9 ft 10 in) in all other cases
The guardrail must sit no more than 300 mm (12 in) from the edge of the opening.
The characteristics of a temporary guardrail
Section 12 of the RSST sets the characteristics of temporary guardrails.
| Item | Requirement |
|---|---|
| Top rail | between 1 m and 1.2 m (3 ft 3 in and 3 ft 11 in) above the floor |
| Intermediate rail | at least one, at mid-height; may be replaced by balusters or panels |
| Toe board | at least 90 mm (3.5 in) at floor level |
| Horizontal load | 900 N (202 lbf) at any point on the top rail |
| Vertical load | 450 N (101 lbf) on the top rail |
| Position | no more than 300 mm (12 in) from the edge of the opening |
Where workers gather in one spot, or where unusual pressure may be applied, the guardrail must be reinforced accordingly.
Temporary guardrail or permanent guardrail?
The distinction matters. The characteristics in section 12 apply to temporary guardrails. A guardrail built into the building must comply with the Building Code in force when it was installed, and both its design and its installation fall to an architect or an engineer.
A permanent work platform, a fixed industrial stair or a walkway bolted to the structure therefore fall under the second regime. That is also what standard CSA A500 covers for building guardrails.
The particular case of roofs
On a low-slope roof, a warning line may, under the conditions set out in the regulation, replace the guardrail, provided it is combined with other protective measures.
What this means for your installations
Designing a permanent protected access means dealing with the hazard at the second level of the hierarchy, that of collective protection. The worker is protected without depending on the correct use of personal equipment, and without prior harness training.
Our stairs, platforms, walkways and rooftop access routes include guardrails from the design stage, sized for the regime that applies to your installation. Where collective protection is not achievable, we design the fall arrest system that takes over.
What about Ontario?
The Ontario framework works differently. Regulation 851 for industrial establishments does not set out a hierarchy of prevention measures comparable to the RSST, and it does not trigger the requirement through a height threshold, but through the configuration of the structure: an open side of a mezzanine, balcony, platform or ramp, or an unguarded opening in a floor or roof.
The characteristics of the guardrail also differ: the top rail sits between 91 cm and 107 cm above the surface to be guarded, a mid rail is required, and a toe board of at least 125 mm applies where tools or objects could fall onto a worker. Structural strength refers back to the Building Code.
The practical consequence for a portfolio spread over both provinces: the common window for top rail height is between 1 m and 1.07 m. That is the height we use by default when a single standard has to suit both Quebec and Ontario.
Your questions about fall protection
Is a harness enough to meet the regulations?
Not automatically. Section 33.2 of the RSST places the harness fourth among prevention measures, after changing the working position, the guardrail and the safety net. The employer must therefore be able to show that the earlier measures are not workable.
At what height is a guardrail required?
Above 3 m (9 ft 10 in) in the general case, and from 1.5 m (4 ft 11 in) where the fall would be into a dangerous liquid or substance, or into a well, a basin, a vat or a tank.
How high must a guardrail be?
On a temporary guardrail, the top rail sits between 1 m and 1.2 m (3 ft 3 in and 3 ft 11 in) above the floor. On a guardrail built into the building, the Building Code requirements apply instead.
Is a toe board mandatory?
On a temporary guardrail, yes: a toe board at least 90 mm (3.5 in) high at floor level. It stops objects from falling over the edge.
What load must a guardrail withstand?
A temporary guardrail must withstand a horizontal load of 900 N (202 lbf) applied at any point on the top rail, and a vertical load of 450 N (101 lbf) on that same rail.
Can a guardrail be replaced on a roof?
On a low-slope roof, a warning line may replace the guardrail under the conditions set out in the regulation, combined with other protective measures. Our advisors will tell you which solution suits your roof.