Past a certain height, a fixed ladder has to be broken up by rest platforms fitted with guardrails. Each flight ends on a platform, and the next one starts offset from it: that is what we call a ladder with staggered flights.
The rules differ by province. In Quebec, section 23 of the RSST requires platforms on ladders over 9 m (29 ft 6 in), placed every 6 m (19 ft 8 in). In Ontario, Regulation 851 requires platforms no more than 9 m (29 ft 6 in) apart, as well as a safety cage above 5 m (16 ft).
Below those thresholds, a fixed ladder with a vertical lifeline or a standard fixed ladder is enough. See the full range on our custom fixed ladders page.
Why rest platforms?
Past a certain height, a continuous climb becomes tiring and dangerous. A platform solves three problems at once.
A safe pause
The climber catches their breath on a protected platform, rather than hanging from their fall arrest system.
A broken-up height
Staggered flights break up the potential fall height, instead of one continuous line up the facade.
Working in pairs
The platform lets people pass each other, pause together and hand equipment from one level to the next.
What we design
- Staggered flights with intermediate platforms fitted with guardrails and a removable gate
- Continuous fall arrest system on each flight, compliant with CSA Z259.2.5 or CSA Z259.2.4
- Suitable roof exit: parapet crossing, exit handrail or side exit
- Access restriction system at the foot of the ladder
- Load transfer studied with you, based on the building structure
Every configuration is unique: where the platforms sit depends as much on the total height as on the openings in the facade, the type of surface and the exit point you need.
A case-by-case design
The higher the access, the more constraints pile up: type of surface, cladding thickness, openings in the facade, how much load the structure can take, site access for lifting the modules.
That is why every project starts with an on-site survey, followed by a drawing you approve before manufacturing. DXF and DWG files are available for your engineering office, and the ladder is delivered in pre-assembled modules, bolted together on site with no welding.
The province of installation is one of the first things we record during the survey: it determines how many platforms are needed, how far apart they sit, and what fall protection goes on each flight.
Our work – fixed ladders with offset flights
What the regulations require
In Quebec, section 23 of the RSST requires rest platforms fitted with guardrails on fixed ladders over 9 m (29 ft 6 in), placed every 6 m (19 ft 8 in). A fall arrest system is also required once the fall hazard exceeds 6 m (19 ft 8 in), so it is installed on every flight.
In Ontario, Regulation 851 requires rest platforms no more than 9 m (29 ft 6 in) apart, as well as a safety cage above 5 m (16 ft). The design therefore differs from a Quebec ladder of the same height, and we adapt it to the province where it will be installed.
Your questions about ladders with staggered flights
At what height are rest platforms required?
In Quebec, above 9 m (29 ft 6 in), with platforms placed every 6 m (19 ft 8 in) and fitted with guardrails. In Ontario, Regulation 851 requires platforms no more than 9 m (29 ft 6 in) apart.
Is a lifeline still required?
In Quebec, yes: a fall arrest system is required once the fall hazard exceeds 6 m (19 ft 8 in), and it is installed on every flight. In Ontario, a safety cage is what is required above 5 m (16 ft). See the ladder with a vertical lifeline ›
How does installation work at height?
The ladder is delivered in pre-assembled modules and bolted together on site, with no welding. Lifting means are defined during the technical visit, based on site access and the height to be reached.
Can a flight be added to an existing ladder?
Sometimes, depending on the existing structure. In Quebec, the modification brings the ladder under current RSST requirements, which we factor into the study.
Where is the roof exit located?
It depends on the building: a parapet crossing with an exit handrail, a side exit or an arrival onto a platform. The exit point is defined during the survey, based on how people will move around the roof.
What is the lead time for a tall installation?
It depends on the height, the complexity of the structure and the lifting means required. It is stated in your quote, after the on-site survey.