What the OSHA 1910.146 and ANSI Z117.1 standards apply to

The OSHA 1910.146 standard establishes mandatory practices and procedures to protect general industry employees from the hazards of entering a permit-required confined space. It does not apply to agriculture, construction, or shipyard employment, which fall under other regulations.

The ANSI Z117.1 standard is a voluntary consensus standard that governs confined space entry in more detail than OSHA's minimum regulatory requirements.

What is a confined space under the OSHA 1910.146 standard

A confined space meets three criteria:

  • It is large enough for an employee to bodily enter and work in.
  • It has limited or restricted means of entry and exit.
  • It is not designed for continuous human occupancy.

A confined space becomes a “permit-required confined space” if it additionally presents at least one of the following hazards: a hazardous atmosphere, material that could engulf a worker, converging walls or a sloping floor that could trap or asphyxiate an occupant, or any other recognized serious safety or health hazard.

What the OSHA 1910.146 standard actually requires

The employer must evaluate the workplace to determine whether permit-required confined spaces are present, and post danger signage if so. An entry permit system is required, with an attendant stationed outside the space.

Unless the retrieval equipment would increase the overall risk of entry or would not contribute to the rescue, a non-entry retrieval system (harness and retrieval line) must be used for each authorized entrant, in accordance with section 1910.146(k)(3).

ANSI Z117.1: a more demanding voluntary standard

The ANSI Z117.1 standard, Safety Requirements for Confined Spaces, often goes beyond OSHA's regulatory requirements on the same subject. [TO BE CONFIRMED] The current edition should be verified; the reference used in our catalogue (ANSI Z117.1-1995) is likely an older edition, as a more recent revision has been published since.

These standards and construction: what is the difference

The OSHA 1910.146 standard explicitly excludes construction sites. Confined space entry in construction is governed separately by Subpart AA of the 1926 regulation (sections 1926.1201 through 1926.1213).

These standards and the Canadian market

In Canada, there is no single federal regulation equivalent to OSHA 1910.146; applicable regulations vary from province to province. The CSA Z1006 standard, Management of work in confined spaces, plays a role comparable to that of ANSI Z117.1: it is a voluntary standard in Canada that governs the complete management of a confined space entry program.

The current edition is CSA Z1006:23 (3rd edition), which supersedes the 2016 and 2010 editions.

Our products for confined space entry

Echelle Canada distributes Class E harnesses (confined space retrieval, see our page on the CSA Z259.10 standard) along with compatible tripods and retrieval winches. The exact compliance of each reference should be verified on the product data sheet before recommending it to a customer.

Frequently asked questions about the OSHA 1910.146 and ANSI Z117.1 standards

What is the difference between a confined space and a permit-required confined space?

Every confined space meets three basic criteria (physical access possible, restricted entry and exit, not designed for continuous occupancy). It becomes a permit-required confined space if it additionally presents a specific hazard: a hazardous atmosphere, engulfment risk, converging walls, or any other recognized serious hazard.

Is a full body harness enough to enter a confined space?

No. A Class E harness (see our page on the CSA Z259.10 standard) is needed for the retrieval attachment point, but confined space entry also requires a permit system, attendant supervision, atmospheric testing and a complete retrieval system, in accordance with the OSHA 1910.146 standard.

Is a retrieval system always mandatory?

Almost always. The OSHA 1910.146 standard requires a non-entry retrieval system for each authorized entrant, unless the equipment would increase the overall risk of entry or would not contribute to the rescue.

Does the OSHA 1910.146 standard apply to construction sites?

No. It explicitly excludes construction, agriculture and shipyard employment. Confined space entry in construction is governed separately by Subpart AA of the 1926 regulation (sections 1926.1201 through 1926.1213).

Is there an equivalent standard in Canada?

The CSA Z1006 standard plays a comparable role, governing the complete management of a confined space entry program. Its application is voluntary in Canada, with applicable regulations varying from province to province.

Need advice on your confined space entry equipment?

The Echelle Canada team helps you choose equipment suited to confined space entry and retrieval.